Home/Products/Battery Testing Equipment
Products / Battery Testing Equipment

Battery Testing Equipment

Cyclers, environmental chambers, and integrated testing systems for battery research, pilot lines, and manufacturing quality control — from the lab bench to production validation.

Featured system

Integrated cycler-chamber system.

One cabinet that combines cell charge/discharge cycling with a −40 to 120 °C environmental chamber and AGV automatic loading — built for unmanned, space-efficient battery test lines.

GRIDENCE ICS-6000 CYCLER · POWER · ENERGY RECOVERY ENVIRONMENTAL CHAMBER −40 to 120 °C 4 CH FIXTURE MULTI- CHANNEL 3-COLOR ALARM N2 / CO2 SUPPRESSION WATER-COOLED AGV AUTO LOAD / UNLOAD ±3.0 mm 1660 mm 2710 mm 2972 mm (D) FOOTPRINT 4.92 m²
GRIDENCE ICS-6000 · Integrated Cycler-Chamber System

ICS-6000

Cell charge/discharge cycling and environmental conditioning in a single water-cooled cabinet — up to 6000 A with > 85% energy recovery, a −40 to 120 °C chamber, a 4-channel fixture with per-channel temperature control, and AGV automatic loading for unmanned lines.

Up to 6000 A−40 to 120 °C4 CH per chamberEnergy recovery > 85%4.92 m² footprintAGV-ready
General01
ProductIntegrated Cycler-Chamber System
ModelGRIDENCE ICS-6000
SeriesIntegrated Cycling System
ConfigurationChamber + cell charge/discharge, single cabinet
Dimensions (W×D×H)1660 × 2972 × 2710 mm
Footprint4.92 m² per unit
LoadingAGV automatic · unmanned-line ready
System coolingWater-cooled
Charge / Discharge — Voltage02
Charge voltage0–6 V
Discharge voltage1.5–6 V (0 V customizable)
Voltage accuracy±0.01% FS
Resolution0.1 mV
Charge / Discharge — Current03
Current range100 / 200 / 400 / 600 / 1200 / 2400 / 4800 / 6000 A
Current accuracy±0.02% FS
Resolution0.1 mA
Current overshoot< ±0.5% · settling < 100 ms
Current response10–90% in < 3 ms
Current switching−90% to +90% in < 5 ms
Ripple current0.1–200 Hz superimposed, 200 A sine
Performance & Data04
Power factor> 0.99
Energy recovery> 85%
Hardware sampling60 kHz
Time record interval1 ms
Min. step interval20 ms
Calibration interval> 1 year
Data storage> 1 TB
Charge modesCC, CV, CP, ramp
Discharge modesCC, CV, CP, CR, ramp
Other modesRest, drive-cycle, pulse, DCIR
Environmental Chamber05
Chamber size1000 × 1000 × 1000 mm (customizable)
Temperature range−40 °C to 120 °C
Temperature accuracy≤ 1 K
Temperature uniformity≤ 2 K
Temperature fluctuation< 0.5 K
Heating rate≥ 2 K/min (no load)
Cooling rate≥ 2 K/min (no load)
Humidity range10–98% RH
Humidity rate1%/min
Humidity accuracy±2% RH
Noise≤ 65 dB (at 1 m)
Chamber coolingAir / water
Safety06
ProtectionPressure-relief valve, door chain, forced exhaust, EM + mechanical locks
Over-temp protectionIndependent, redundant, adjustable high/low limits
Fire detectionSmoke + gas (CO, HC, H2)
Fire suppressionN2 / CO2 gas or water spray
Air purgeRapid dehumidify & flush, strong exhaust
Enclosure & doorExplosion-proof design
Safety PLCManual / auto / remote suppression, independent alarm cut-off
AlarmThree-color signal tower
EUCAR hazard levelLevel 7
Multi-Channel Fixture07
Applicable cellsPrismatic & blade, various sizes
Channels4 CH per chamber
Current range±600 A
Temperature range−40 °C to 120 °C
Temperature accuracy≤ 1 K
Temperature uniformity≤ 0.5 K
Temperature fluctuation< 0.5 K
Heating / cooling rate≥ 5 K/min (no load)
Temperature controlPer-channel independent
InterfacesCurrent, signal, coolant; water-cooling plate
Load accuracy±3.0 mm (AGV)
Product families

The full testing range.

Battery Cyclers

Charge/discharge cycling for cells and modules across R&D and quality-control workflows.

Environmental Chambers

Controlled-temperature and -humidity testing for battery performance and reliability.

Integrated Cycler-Chamber Systems

Combined cycling and environmental control in a single integrated platform.

Battery Testing Platforms

Configurable platforms for development and validation programs.

Laboratory Solutions

Testing solutions for universities and research institutes.

Applications
Battery R&DPilot LinesManufacturing Quality ControlUniversities & Research Institutes

Detailed model specifications available on request — contact us for configurations suited to your program.

Planning a test program?

Tell us your cell formats and throughput, and we’ll recommend a configuration.

Request a quote